Plane grinding wheel application common problems and solutions

    2019-06-10   reading

    Plane grinding wheel application common problems and solutions

     1. Reasons and solutions for uneven or non-parallel surface

           The feed rate is too large: reduce the amount of feed, especially during the fine grinding stage

           Workpiece burn: use the correct size, hardness

           Residual stress of workpiece: Elimination of residual stress before grinding

           The electromagnetic clamp is dirty: clean the electromagnetic clamp before fine grinding

           The grinding wheel shaft is not adjusted well: re-adjustment makes the grinding wheel shaft parallel to the table

     grinding wheel

    2. Reasons and solutions for scratches on the surface of the workpiece

           Coolant is not clean: clean the cooling tank or replace the coolant

           The grinding wheel is too soft: use a harder grinding wheel

           The grinding wheel is too thick: use a harder grinding wheel or slow down the dressing speed of the grinding wheel

           Trimming problem: check dressing device


     3. Reasons and solutions for the vibration of the workpiece

           Spindle bearing wear: check spindle bearing

           The grinding wheel has a beating: re-trimming the grinding wheel and checking the installation

           The grinding wheel is too hard: use a softer grinding wheel

           Grinding wheel organization is too tight: use a wheel with a more open structure

           Loose clamping: check flange bolts

    grinding wheels

     4. The workpiece burns or stops in the middle of grinding

           The grinding wheel is hard: use a softer or thicker or more open tissue wheel

           Countertop speed is too slow: increase table speed

           Grinding contact surface is too large: reduce traverse speed

           The grinding wheel is too thin: the grinding wheel is rougher

           The amount of feed is too large: reduce the amount of feed

           Coolant flow is too small: increase coolant flow


    facebook linkin Twitter google